Solution System 107Service Manual – SC500
Maintenance and Adjustments
Cleaning the Detergent Solution Tank and Filter
1. Drive the machine on a level oor.
2. Ensure that the machine is off and the operator key has been removed.
3. Drain the detergent solution tank with the level hose. Then, rinse the tank with clean water.
4. Close the detergent solution valve (A) (Figure 5). The valve (A) is closed when it is in position (B) and it
is open when it is in position (C).
5. Remove the transparent cover (D) and the gasket (E), then remove the lter strainer (F). Wash and
rinse them, then ret them carefully onto the lter support (G).
6. Open the valve (A).
D
F
E
G
AC
B
Figure 5