27
• “Fan Out”: Settings for the control of the exhaust fan.
• “Drying Time”: Time in minutes the exhaust fan continues to run after the steam bath
time has elapsed to dry the steam bath cabin (Factory setting: 20 min-
utes, Setting range: 1...60 minutes).
• “Hysteresis”: Hysteresis value in °C (steam bath operation) or %rh (caldarium opera-
tion) to switch on and off the exhaust fan (Factory setting: 4 °C/18 %rh,
Setting range: 2...60 °C/6...65 %rh).
Note: in steam bath operation the exhaust fan switches off if the tempera-
ture or the humidity in the steam bath cabin drops half of the selected
hysteresis value below the set setpoint value, and switches on if the
temperature or the humidity in the steam bath cabin increases half of
the selected hysteresis above the set setpoint value.