Page #58 background imageLoading...
Page #58 background image
Repair
6-8
Part 161250002
E 2018 Nordson Corporation
8. See Figure 6-7, View C. Pull the cable connectors out of the bottom of
the handle. Disconnect the power supply connector from the gun cable
connector by inserting a small flat-bladed screw driver in the slot of the
power supply connector to release the catch.
9. Carefully disconnect the round trigger connector from the trigger switch
connector.
10. Pull the cable out of the handle base, feeding the connectors through
the base one at a time.
27
31B
39
32
25
27
Trigger
Power Supply
Ground
VIEW A
VIEW B
VIEW C
26
Figure 6-7 Cable Replacement
25. M3 x 6 screw
26. M3 lock washer
27. Ground pad
31B. M3 x 20 screws
32. E-ring
39. Handle base

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson Encore Series and is the answer not in the manual?

Nordson Encore Series Specifications

General IconGeneral
Maximum Output Voltage100 kV
Power SourceElectric
Maximum Powder Output20 lbs/hr (9.07 kg/hr)
Air Consumption10-15 CFH (4.7-7.1 L/min)
ApplicationPowder coating
TechnologyElectrostatic
Maximum Flow Rate20 lbs/hr (9.07 kg/hr)
Weight1.5 lbs (0.68 kg)