4-8 Section 060-INDP-410 Command and Message Guide
297-6201-502 Standard 01.02 September 2000
To assign or change an alarm event, alarm type, or alarm level for the active
processor only, enter the following command:
>ERRMAP event alarm level (cr)
The system responds by displaying an ERRMAP printout with the changed
data. Be sure to issue the SITDAT WRITE and LINIT commands to save new
data to disk and send the new values to the CP.
19 OFFLIN DSK FULL Major 0
20 DSK STORE LIMIT Critical 0
21 DISK WRITE FAIL Major 2
22 DSK INDEX ERROR Minor 0
23 NO INDEX FILE Major 0
24 DIRECTORY FULL Critical 0
25 SITE FILE ERROR Minor 0
26 STAT FILE ERROR Minor 0
27 EXCESS INV BLKS Minor 0
28 CP NOT AVAIL. Major 1
29 CP FAULT Major 1
30 DSK ERROR ALARM Critical 0
31 DISK MODE ALARM Major 0
32 DSK CARD HW ERR Major 2
33 DISK ER MESSAGE Minor 0
Table 4-4
ERRMAP device/event names
Event Event name Alarm Level
Sheet 2 of 2