Section 060-INDP-410 Command and Message Guide 4-11
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
CP LOOP ACT
CP LOOP STDBY
CP MEMWRITE
CP TEST ACT
CP TEST STDBY
CP VS ACT
CP VS STDBY.
CP BOOT ACT
CP BOOT ACT, a maintenance command, allows the user to direct the BMC
to reload the CP on the active processor by sending it the files listed in the file
BOOTCP.
Example of command usage
To load the contents of the BOOTCP file to the active CP, issue the following
command:
>CP BOOT ACT (cr)
The system responds with the following:
CP RESTART
CP RELOAD
CP RESTART
CP ACTIVE
where:
filename - name of the BOOTCP file.
Note: Use this command only when specifically called for as part of
another procedure; maintenance or special.
CP BOOT ADD
CP BOOT ADD, a maintenance command, adds a new file name in the
BOOTCP file.
Example of command usage
To add a new file name to the BOOTCP file, issue the following command:
>CP BOOT ADD filename version (cr)
where:

Table of Contents

Other manuals for Nortel DMS-10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel DMS-10 Series and is the answer not in the manual?

Nortel DMS-10 Series Specifications

General IconGeneral
BrandNortel
ModelDMS-10 Series
CategoryTelephone System
LanguageEnglish

Related product manuals