Chapter 7 Diagnosing Problems
330
HMR BANK FAN
FLT
Yes Sensors cannot
detect current in
fan circuit.
Check that fan cable is
connected. Check for
obstruction of vents and
fan airway; remove any
obstructions. Check for
items beneath the printer
blocking cabinet vents.
Power back on the
printer. If this message
recurs, contact your
authorized service
representative.
1
ILL EXT BUS ACC* No Fatal firmware
error on controller
board.
Contact your authorized
service representative.
1
ILLGL OPR ACCSS* No Fatal firmware
error on controller
board.
Contact your authorized
service representative.
1
INCOMPAT E-NET Yes Incompatible
network interface
card (NIC) is
installed.
Install a compatible NIC
to the printer then reboot.
If this message still
appears, contact your
authorized service
representative.
1
INTAKE FAN FAULT Yes Sensors cannot
detect current in
fan circuit.
See description for HMR
BANK FAN FLT.
Table 15. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation Solution

Table of Contents

Other manuals for Oki MICROLINE MX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MICROLINE MX Series and is the answer not in the manual?

Oki MICROLINE MX Series Specifications

General IconGeneral
BrandOki
ModelMICROLINE MX Series
CategoryPrinter
LanguageEnglish

Related product manuals