The Ultimate Ice Resurfacer 11
EMERGENCY STOP
The EMERGENCY shut o button can be used to shut down the whole ice resurfacer in an
emergency. The EMERGENCY shut o button is located at the front left, in front of the steering
wheel.
Switch-O: Depress the knob on the switch to shut o the power (disconnect the circuit).
Switch-On: To switch the ice resurfacer back on again, pull out the knob until it locks into place.
The normal switch-on procedure must then be executed from the beginning. ( section 7.1.1 )
Fig. 1.1: Emergency Shut o switch on the OLYMPIA
The Emergency Shut o switch turns o the whole ice resurfacer, except for the battery
discharge indicator. The battery discharge indicator is mounted on the battery to save
the stored data. When the battery connector is disconnected, the whole ice resurfacer is
switched o too, with the exception of the battery discharge indicator.
Limitation: The (+) contact of the EMERGENCY STOP switch still carries the potential of the
(+)Ub port of the battery!