The Ultimate Ice Resurfacer 12
Charging of the battery is also interrupted when the Emergency shut o switch is pressed. If
the charger is not working, please rst check whether the Emergency shut o switch has been
pressed.
Caution!
Do not attempt to operate the ice resurfacer until the reason for the shut down has been
discovered and corrected.
If the EMERGENCY STOP circuit is activated, all power to the OLYMPIA is switched o. The brake
accumulator remains under pressure, but can be depressurised by simply pressing the brake
pedal several times.
The removal of guards or safety devices or rendering them inoperable while the ice
resurfacer is in operation is prohibited.
Guards and safety devices may only be removed or put out of operation for repair or
maintenance purposes after the main switch has been turned o and measures taken
to prevent it from being switched back on again, and after the ice resurfacer has been
depressurised.
Tools are needed to open all covers and panels.