3-46
Bank/Func-
tion
POSITION/OFFSPEED/ONSetting
range
Function nameCam/Parame-
ter
b (b)
1 Origin
compensation
value
0 to 359
(0 to 719)
(see note 2)
Sets origin
compensation value
(angle data).
Factory setting “0.”
---
2 Backlash
compensation
value
0 to 179
(0 to 359)
(see note 2)
Sets backlash
compensation value
(angle data).
Factory setting “0.”
---
3 Advance angle
compensation
value 1
0 to 1600
(0 to 800)
(see note 2)
Sets speed data for
advance angle
compensation value
1.
Factory setting “0.”
---
0 to 359
(0 to 719)
(see note 2)
--- Sets angle data for
advance angle
compensation value
1.
Factory setting “0.”
4 Advance angle
compensation
value 2
0 to 1600
(0 to 800)
(see note 2)
Sets speed data for
advance angle
compensation value
2.
Factory setting “0.”
---
0 to 359
(0 to 719)
(see note 2)
--- Sets angle data for
advance angle
value 2.
Factory setting “0.”
5 Advance angle
compensation
value 3
0 to 359
(0 to 719)
(see note 2)
--- Sets angle data for
advance angle
compensation value
3 (advance angle
compensated
position).
Factory setting “0.”
6 Baud rate 1, 2 1: 9,600 bps
(factory setting)
2: 19,200 bps
---
c (c)
--- Cam protect --- Protection can be
set or released for
each cam number
or for all cams in a
bank number.
(Factory setting:
“unprotected”)
Protect can be set
or released for each
cam number or for
all cams in a bank
number (Factory
setting
“unprotected”)
d (d)
--- Teaching --- Present Resolver
angle can be input
as ON angle data.
Present Resolver
angle can be input
as OFF angle data.
Operation Chapter 3