3-47
Bank/Func-
tion
POSITION/OFFSPEED/ONSetting
range
Function nameCam/Parame-
ter
F (f)
--- One-direction
function setting
0 to 2 --- 0: One-direction
function disabled
(factory setting)
1: Enabled in
forward direction
2: Enabled in
reverse direction
H (h)
1 Backlash
compensation
enable/disable
setting
0, 1 0: Backlash
compensation
disabled (factory
setting)
1: Backlash
compensation
enabled
---
2 Advance angle
compensation
enable/disable
setting
0, 1 0: Advance angle
compensation
disabled (factory
setting)
1: Advance angle
compensation
enabled
---
3 Output hold 0, 1 0: Output hold
disabled (factory
setting)
1: Output hold
enabled
---
4 Present value
output setting
0 to 4 0: No present value
output function
(factory setting)
1: 4-digit present
angle (no units)
2: 4-digit number of
rotations (no
units)
3: Automatic
switching of
3-digit present
angle and
number of
rotations (with
units)
4: Automatic
switching of
4-digit present
angle and
number of
rotations (with
units)
---
Operation Chapter 3