1Function level 2
1Function level 2
3-90
H Related Parameters (SET Mode)
D Baud Rate Setting
Function
No.
b (b)
Parameter
No.
6 Setting range 1, 2
The Baud rate setting function sets the baud rate for data transmission.
The baud rate settings are explained below.
1: 9,600 bps (factory setting)
2: 19,200 bps
Set the same baud rate for both the Master and Slave Units.
Note This parameter is enabled after the power has been turned OFF and then ON again.
Operation
Origin
compensation
value
Backlash compensation value Baud rate
Use the mode selection switch to change to SET mode.
When the baud rate (Function No. b, Parameter No. 6) is displayed, the present baud rate settings
flash in the SPEED/ON display.
Use the Up and Down Keys to change the data.
Press the Set Key and the data will remain lit for approximately one second, the setting will be con-
firmed, and the display will resume flashing.
If the baud rate setting has been changed, turn OFF the power supply and turn it ON again.
D Data Transfer (Slave Unit Settings)
Function
No.
t (t)
Parameter
No.
0 Setting range ---
Use this parameter to make the settings on the Slave Unit to enable data transfer.
D Data Transfer (Master Unit Settings)
Function
No.
t (t)
Parameter
No.
1 Setting range 0 to 3
Use this parameter to make the settings on the Master Unit to enable data transfer.
The settings are shown below.
0: Disabled (factory setting)
1: Data read (Reads cam programs and parameters from the Slave to the Master Unit.)
2: Data write (Writes cam programs and parameters from the Master to the Slave Unit.)
3: Data verification (Verifies the Master programs and parameters against the Slave programs and
parameters.)
Operation Chapter 3