3-91
Operation
Data transfer Data transfer (Slave Unit settings)
Data transfer (Master Unit settings)
D Slave Cam Positioner Settings
Use the Bank/Function Key to set data transfer (Function No. t) and press the Set Key. “0” (Slave Unit
settings) will appear in the Cam/Parameter No. display.
The settings for the Slave Unit have now been completed. While this data is displayed, make the set-
tings for the Master Cam Positioner Unit.
D Master Cam Positioner Settings
Use the Bank/Function Key to set data transfer (Function No. t) and press the Set Key. “0” (Slave Unit
settings) will appear in the Cam/Parameter No. display.
Press the Cam/Parameter Key to display “1” (Master Unit settings)
”0” will flash in the SPEED/ON display.
Use the Up and Down Keys to set the data.
0: Disabled (factory setting)
1: Data read (Reads cam programs and parameters from the Slave to the Master Unit.)
2: Data write (Writes cam programs and parameters from the Master to the Slave Unit.)
3: Data verification (Verifies the Master programs and parameters against the Slave programs and
parameters.)
If the incorrect setting is made, e.g., if data read (setting “1”) and data write (setting “2”) settings are
mistaken, important data may be deleted. Check again that the correct setting has been selected.
Press the Set Key to start communications with the Slave Cam Positioner Unit. During the transfer, the
data being transferred (P: parameter; b1 to b8: bank numbers 1 to 8) will be appear in the POSITION/
OFF display. The communications will take approximately 40 seconds to be completed.
Note 1. The data being transferred will be displayed on the Master Unit only.
Note 2. The display will not include “b5” to “b8” for 720 resolution.
When the communications have been completed normally, press the Set Key to return to the previous
display.
If a communications error has occurred, the error code will appear in the SPEED/ON display. Check
the error and press the Clear Key. The error will be cleared. Press the Set Key to return to the previous
display.
Additional Information on the Copy Function
S Data Transferred
All cam programs and parameters will be transferred from one Cam Positioner Unit to the other.
The contents of Function No. t (data transfer) and Function No. P (pulse output setting) will not be
transferred.