2-28
Note 5. Some display examples are given below.
w Present angle display w Resolver speed display
(see
note)
(blank)
(blank)
rpm
Note Write “deg” in the space when using a no display Unit.
H Connecting a M7F Display Unit
Use a 3F88L-CGjjjS Cam Output Cable to connect the M7F Display Unit.
3F88L-160/162
Cam Positioner
3F88L-CGjjjS
Cam Output Cable
M7F Display Unit
D Functions
The present angle (in degrees) or the Resolver speed (r/min) can be displayed on a 4-digit numeric
Display Unit. The display data is set using the present value display function parameters.
Note The M7F Display Unit does not have a function to change the unit of display. Do not use this Unit in
automatically switching display mode.
D Unit Models Used
Name Model Remarks
4-digit Display Unit, character height
M7F-4D1R (red)
Select the appropriate Unit
b d h dil h
gpy, g
14 mm
M7F-4D1G (green)
pp p
based on the display character
height requirements for units
4 digits + Display Unit (Units),
h hih
M7F-4D1RT (red)
height, requirements
f
or units
display, and color of displayed
gpy(),
character height 14 mm
M7F-4D1GT (green)
display
,
and color of displayed
characters.
Units Nameplate, character height
M7F-1 (no display)
characters.
When usin
g
a Unit with units
p, g
14 mm
M7F-RPM-1 (r/min)
When using a Unit with units
display, select a Unit Nameplate
4-digit Display Unit, character height
M7F-4D2R (red)
py p
with the same height character
display There is no Unit
gpy, g
25 mm
M7F-4D2G (green)
di
sp
l
ay.
Th
ere
i
s
no
U
n
it
Name
p
late for “de
g
rees.” Select
4 digits + Display Unit (Units),
h hih
M7F-4D2RT (red)
Nameplate for degrees
.
Select
the “no display” Unit Nameplate
gpy(),
character height 25 mm
M7F-4D2GT (green)
py p
instead.
Unit nameplate, character height
M7F-2 (no display)
p, g
25 mm
M7F-RPM-2 (r/min)
Display Unit Connector XG5M-2035-N (separately wired
pressure-welded type)
One Display Unit Connector is
required.
Display Unit Connector Cover
XG5S-1001
Two XG5S-1001 Covers or one
XG S C i i d
py
XG5S-2012
XG5S-2012 Cover is required.
Cam Output Cable
1 m 3F88L-CG001S
One Cable is required.
p
3 m 3F88L-CG003S
q
Design Chapter 2