EasyManuals Logo

Omron CX-INTEGRATOR - V1.1 User Manual

Omron CX-INTEGRATOR - V1.1
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #247 background imageLoading...
Page #247 background image
6-10 Creating and Editing I/O Comments
6-9-6 Starting Remote I/O Communications
6-10 Creating and Editing I/O Comments
Component - Edit I/O Comment
The CX-Integrator can be used to add comments to I/O data of slaves.
The I/O comments can be checked while making I/O allocations to the master.
Note
No I/O comments can be created or edited for a device if the device is not designed to
have I/O data.
To edit I/O comments, use the following procedures.
1. Select the device.
2. Select Component - Edit I/O Comment (or select the slave, click the right mouse
button, and select Edit I/O Comment).
The following dialog box will be displayed.
An I/O comment can be created for each connection supported by the device. If
areas have been already allocated to the master, they will be displayed.
Note
If an area is not allocated to a master, the display will show 0000, the default area.
Edited I/O comments can be exported in the CSV format by selecting Export and I/O
Comment List. Part of I/O comment data exported in the CSV format can be opened
in spreadsheet software and used for CX-Programmer variable tables.
6-43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CX-INTEGRATOR - V1.1 and is the answer not in the manual?

Omron CX-INTEGRATOR - V1.1 Specifications

General IconGeneral
BrandOmron
ModelCX-INTEGRATOR - V1.1
CategorySoftware
LanguageEnglish

Related product manuals