Sup-
port
Processing item
Sup-
port
Processing item
Sup-
port
Glue Bead Inspection OK Transfer Position Data OK
Position Compensation OK Calc Axis Move OK
Filtering OK Calc Axis Move by Multi-
point
OK
Back Ground Suppression OK Detection Point OK
Brightness Correct Filter OK Camera Calibration OK
Color Gray Filter OK Data Save OK
*1. Not supported for 3 or more lines.
*2. DI Register in the measurement mode is not supported.
Non-stop Adjustment Mode
Non-stop Adjustment Mode allows you to change and adjust the measurement flow without having to
stop the measurement processing during operation.
You use saved image files to adjust measurement flows. You can apply a modified measurement flow
while the Controller is in RUN mode.
Lines 0 and 1 are used simultaneously for the execution of the Non-stop Adjustment Mode.
While the measurement process is executed for line 0, you modify and adjust the measurement flow
for line 1.
Typical Application for Non-stop Adjustment Mode
Before operation During operation
Create a setup so that
the NG images are saved.
Select [Transfer data] to
transfer data
on line 0 to line 1.
Start the operation
NG results.
Click [Switch Screen] to
switch to the Non-stop
Adjustment Mode.
Perform the re-measurement
with the adjusted conditions
and check if the settings are
properly set.
Adjust the measurement
conditions and judgement
conditions as required.
Re-measure the NG image to
analyze the cause of the NG.
Select [Non-stop data
transfer] to transfer data
on line 1 to line 0.
Click [Switch Screen]
to exit
the Non-stop Adjustment Mode.
Perform measurements using
the modified conditions.
1
In the Main Window for line 0, select Transfer data from the Function menu.
The settings for line 0 are transferred to line 1.
4 Setting the Controller
4 - 23
FH/FHV Series Vision System User’s Manual (Z365-E1)
4-4 Setting Operation Mode [Startup Settings]
4
4-4-1 Setting the Operation Mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FHV7 series and is the answer not in the manual?

Omron FHV7 series Specifications

General IconGeneral
BrandOmron
ModelFHV7 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals