Symptom Correction
Improving processing speed
with Parallelize Task proc-
essing item
Parallel processing may not reduce transaction times as much as expected
due to the processing time of each task, and the number of CPU cores.
Before commissioning the system, always check the transaction time with
the actual measurement flow and image.
Getting and setting system
data under Parallelize Task
processing items
Do not get or set user data and system data within the range of a Parallelize
Task processing item.
4 Setting the Controller
4 - 37
FH/FHV Series Vision System User’s Manual (Z365-E1)
4-4 Setting Operation Mode [Startup Settings]
4
4-4-2 Parallel Processing