Item
Setting value
[Factory default]
Description
BUSY ON
[Unchecked]
Checked
Check the box to turn on BUSY during data setting.
Operation ident - Sets when controlling the button operation with security.
Set the identifier name to write to Message\FZ-Security_Set-
ting_xxx.msg.
Status - Sets the status for the data setting button.
Enable - Specifies the variable to store the data setting button status from
the variable assignment window. However, only the scene varia-
ble or system variable can be specified.
Refer to Assigning variables on page 5 - 60.
The variable value is 0. : Set the data setting button to disabled
state.
The variable value is other than 0. : Set the data setting button to
enabled state.
Selected - Specifies the variable to store the data setting button status from
the variable assignment window. However, only the scene varia-
ble or system variable can be specified.
Refer to Assigning variables on page 5 - 60.
The variable value is 0. : Set the data setting button to normal
state.
The variable value is other than 0. : Set the data setting button to
selection state.
Front/Back - Specifies the variable to store the data setting button status from
the variable assignment window. However, only the scene varia-
ble or system variable can be specified.
Refer to Assigning variables on page 5 - 60.
The variable value is positive. : Move window to the front.
The variable value is negative. : Move window to the back.
The variable value is 0. : Do not move the window.
Control - Sets when changing the status for the numerical value input win-
dow using a macro.
Control ID 0 to 999 The ID used to identify the operation target if using the macro Rai-
seOptionEvent relationship to carry out operations.
Text & Font Setting - Display the setting contents for Text Setting, Font Setting, and
Color Setting.
Text Setting - Sets character data to display.
Data Type
[Direct Input]
Variable
Sets text data to display on the button.
Direct:
Directly input to the Text Data.
Variable:
Specify a system variable or a scene variable of character
string type that defines a character string to display.
Text Data 0 to 128 characters Specifies text data to display on the button.
Data Type
(Selected)
[Direct Input]
Variable
Sets text data to display at the button selection.
Direct:
Directly input to the Text Data.
Variable:
Specify a system variable or a scene variable of character
string type that defines a character string to display.
Text Data
(Selected)
0 to 128 characters Specifies text data to display at the button selection.
8 Setting Windows
8 - 57
FH/FHV Series Vision System User’s Manual (Z365-E1)
8-3 Arranging Windows [Layout Functions]
8
8-3-23 Data Settings Button Window (MDI_SetDataBtn.dll)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FHV7 series and is the answer not in the manual?

Omron FHV7 series Specifications

General IconGeneral
BrandOmron
ModelFHV7 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals