138 LD-60/90 Platform User's Manual 11970-000 Rev M
8.7 Replacing Non-Periodic Parts
Symptoms: When the docking station is switched on, the blue power light does not come on.
(Verify that the unit is plugged into AC power.)
WARNING: ELECTROCUTIONRISK
Unplug power from the docking station before starting. Remove the power cord
from the charger.
Remove the fuse assembly by squeezing the two tabs toward each other, and pulling it away
from the docking station. See the following figure.
Figure 8-8. Docking Station Fuse
The fuses are available from the factory as P/N 02212-000L. Equivalent fuses are available gen-
erically. The fuses need to be 250 V, 10 A, and Time-lag. An example of a fuse that meets this
is:
LittelFuse 0215010.XP, 5x20 mm cartridge type
Docking Station Internal Fuse
NOTE: The following procedure applies only to legacy docking stations. There
are no user-serviceable fuses on the current docking station.
Symptoms: When the docking station is switched on, the blue power light does not come on,
but the docking station can charge a battery manually.
WARNING: ELECTROCUTIONRISK
Unplug power from the docking station before starting. The docking station
cover is NOT interlocked. Remove the power cord at the charger.
1.
Remove the ten screws from the back cover of the docking station.
Two of these are on the sides, near the bottom.