166 LD-60/90 Platform User's Manual 11970-000 Rev M
10.3 Docking Station Specifications
Battery Outputs
Nominal Qty Actual
Maximum
Current
Description
5 VDC 1 5 VDC±5% 1 A Switched Aux power
12 VDC 1 12 VDC±5% 1 A Switched Aux power
20 VDC 1 20 VDC±5% 1 A Switched Aux power
22 - 30 VDC 2 battery 4 A Switched
22 - 30 VDC 1* battery 10 A Switched
22 - 30 VDC 1* battery 10 A Safe- Switched
* 10 A Switched and 10 ASafe- Switched share the 10 A of current.
10.3 Docking Station Specifications
Description Specification
Current 8 A
Thermal fuse in AC power switch
(10 A Time-lag fuse at switch for legacy dock)
Contacts 2
Voltage 100-240 VAC, 50/60 Hz
Power consumption 800 W
Short circuit current rating (SCCR) 1500 A
Humidity 5% to 95% non-condensing
Temperature 5 to 40°C
Dimensions - WxDxH
with Floor plate
349 x 369 x 315 mm
495 x 495.5 x 317 mm
Weight 8.2 kg
Mounting Wall bracket, directly to floor, or on floor with floor plate
Indicators Power on - blue
Charging - yellow
Connector For out-of-platform battery charging

Table of Contents