Chapter 7: Operation
7.4 Operator Panel
The Operator screen, E-Stop, Brake-release, ON, and OFF can be "moved" using a single con-
nector (the HMI Panel connector). This allows you to put many of the more common operator
controls somewhere on your payload structure with just one cable.
Figure 7-4. Standard Operator Panel (units are mm)
Callout Description Callout Description
A Emergency Stop E 15 Pin High Density D-Sub Punch
B Brake Release F 2x
0
.120 Through Hole
C On Button G 7x 0.213 Through Hole
D Off Button
A larger Operator panel, with a touchscreen, is available as an option. See Touchscreen on
page 158. Many other connections are available. For details and specifications of available con-
nections, refer to Connectivity on page 77.
Screen
The screen is a color TFT, 320 x 240 pixels, 8.89cm diagonal. It can display 256K colors, and is
backlit.
NOTE: If the backlight times out, tapping lightly on the screen turns it back on.