Chapter 6: Connectivity
Callout Description Callout Description
A Standard Equipment E Load
B User-Supplied Equipment F Outputs 1-16
C Wiring Terminal Block G Equivalent Circuit
D Typical User Loads
Analog I/O
Connector type HDB15M
Pin No. Designation Notes
1 ANALOG_IN1 0 10 V Range
2 ANALOG_IN2 0 10 V Range
3 ANALOG_IN3 0 10 V Range
4 ANALOG_IN4 0 10 V Range
5 ANALOG_IN5 0 30 V Range
6 ANALOG_IN6 0 30 V Range
7 ANALOG_IN7 0 30 V Range
8 ANALOG_IN8 0 30 V Range
9 ANALOG_OUT1 0 20 V Range
10 ANALOG_OUT2 0 20 V Range
11 ANALOG_OUT3 0 20 V Range
12 ANALOG_OUT4 0 20 V Range
13, 14, 15 GND
l
The 0-10 V analog inputs have an input impedance of about 35 kΩ.
l
The 0-30 V analog inputs have an input impedance of about 110 kΩ.
l
The analog outputs have an output impedance of about 200 Ω.
The maximum output current of each analog output is 10 mA. Exceeding the maximum
output current will result in damage to the analog output module.
Aux Sensors
Connector type HDB15M
Use Low Front Laser, optional Side Lasers
11970-000 Rev M LD-60/90 Platform User's Manual 85