Enable and Verify a DIMM
e.
Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output indicates that
POST did not detect any faults:
-> start /HOST/console
...
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note - The server might boot automatically at this point. If so, go to step f. If the server remains
at the OpenBoot prompt (ok) go to the next step.
f.
If the server remains at the OpenBoot prompt, type boot.
g.
Return the virtual keyswitch to Normal mode.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
h.
Switch to the system console and type:
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in “Identify
Faulted Components” on page 23.
4.
Switch to the Oracle ILOM command shell.
5.
Type:
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CM/CMP/BOB21/CH0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
104 SPARC T8-1 Server Service Manual • January 2022