Verify the SPM
12.
Verify that the SPM date is correct.
-> show /SP/clock
/SP/clock
Properties:
datetime = Tue Sep 07 08:09:59 2013
timezone = GMT (GMT)
uptime = 0 days, 00:01:18
usentpserver = disabled
->
a.
Set the datetime property, if necessary.
-> set /SP/clock datetime=MMDDhhmmYYYY
b.
Set the timezone property, if necessary.
-> set /SP/clock timezone=3-to-4-characters
where the timezone value equals a three- or four-character timezone abbreviation, such as
EST.
Related Information
■
Oracle ILOM documentation
■
“Remove the SPM” on page 122
■
“Verify the SPM” on page 126
Verify the SPM
1.
Verify that the SP Status LED is illuminated green.
Note that the LED flashes green while the SPM initializes the Oracle ILOM firmware. See
“Interpreting LEDs” on page 27 for information about the status of the SP LED.
2.
Use the Oracle ILOM show faulty command to verify that the fault has been
cleared.
See “Identify Faulted Components” on page 23 for more information on using the show faulty
command.
Consider these possibilities.
126 SPARC T8-1 Server Service Manual • January 2022