Verify a Fan Module
6.
Return the Server to Operation.
7.
When the server is powered, verify the new fan module. See “Verify a Fan
Module” on page 75.
Related Information
■
“Return the Server to the Normal Operating Position” on page 158.
■
“Remove a Fan Module” on page 71
■
“Verify a Fan Module” on page 75
Verify a Fan Module
1.
Verify that the Service Required LED on the replaced fan module is not lit.
See “Fan Module LEDs” on page 70.
2.
Verify that the Top Fan LED and the Service Required LED on the front of the
server are not lit.
See “Front Panel Controls and LEDs” on page 28.
Note - If you are replacing a fan module when the server is powered down, the LEDs might
stay lit until power is restored to the server and the server can determine that the fan module is
functioning properly.
3.
Use the Oracle ILOM show faulty command to verify that the fault has been
cleared.
See “Identify Faulted Components” on page 23 for more information on using the show faulty
command.
Consider these two possibilities.
■ If the previous steps did not clear the fault, see “Detecting and Managing
Faults” on page 21 for information about the tools and methods you can use
to diagnose component faults.
■ If the previous steps indicate that no faults have been detected, then the
component has been replaced successfully. No further action is required.
Related Information
■
“Determine Which Fan Module Is Faulty” on page 71
Servicing Fan Modules 75