Reactivate RAID Volumes
where inactive_volume is the name of the RAID volume that you are activating. For example:
ok 0 activate-volume
Volume 0 is now activated
Note - For more information on configuring hardware RAID on the server, refer to
“Configuring Hardware RAID” in SPARC T8 Series Servers Administration Guide.
8.
Unselect the SCSI device.
ok unselect-dev
9.
Confirm that you reactivated the volume.
ok probe-scsi-all
/pci@301/pci@2/scsi@0
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
Target a
Unit 0 Removable Read Only device TEAC DV-W28SS-R 1.0C
SATA device PhyNum 3
Target b
GB Unit 0 Disk SEAGATE ST914603SSUN146G 0868 286739329 Blocks, 146
SASDeviceName 5000c50016f75e4f SASAddress 5000c50016f75e4d PhyNum 1
Target 389 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 33b2999bca4dc677 VolumeWWID 03b2999bca4dc677
/pci@300/pci@2/usb@0/hub@3/storage@1/disk@0
Unit 0 Removable Read Only device AMI Virtual CDROM 1.00
ok probe-nvme-all
/pci@303/pci@2/pci@0/pci@7/nvme@0
NVME Controller VID: 8086 SSVID: 108e SN: PHLE719200D06P4O MN: 7335940:ICDPC2DD2ORA6.4T
FR: QDV1RD06 NN: 1
Namespace ID: 1 Size: 6.401 TB
/pci@303/pci@2/pci@0/pci@6/nvme@0
NVME Controller VID: 8086 SSVID: 108e SN: PHLE7192009Z6P4O MN: 7335940:ICDPC2DD2ORA6.4T
FR: QDV1RD06 NN: 1
Namespace ID: 1 Size: 6.401 TB
/pci@303/pci@2/pci@0/pci@5/nvme@0
NVME Controller VID: 8086 SSVID: 108e SN: PHLE719200736P4O MN: 7335940:ICDPC2DD2ORA6.4T
FR: QDV1RD06 NN: 1
Namespace ID: 1 Size: 6.401 TB