Page #29 background image
Interpreting LEDs
No. LED or Control Description
4 Power Button See “Removing Power From the Server” on page 45 and “Power On the Server
(System Power Button)” on page 160.
5 SP OK indicator Indicates these conditions:
Off – AC power might not have been connected to the power supplies, or an SPM
error has occurred and service is required.
Steady on – SP is running in its normal operating state. No service actions are
required.
Slow Blink – SP is initializing the Oracle ILOM firmware.
6 Fan Module Fault LED (amber) Indicates these conditions:
Off – Steady state, no service action is required.
Steady on – A fan module failure event has been acknowledged and a service action
is required on at least one of the fan modules.
7 Server Power Supply Fault LED
(amber)
Indicates these conditions:
Off – Steady state, no service action is required.
Steady on – A fault has been detected on one of the two power supplies.
8 Server Overtemp LED (amber) Indicates these conditions:
Off – Steady state, no service action is required.
Steady on – A temperature failure event has been acknowledged. A temperature
limit has been exceeded, and a service action is required.
Related Information
“Rear Panel Controls and LEDs” on page 30
“Checking for Faults” on page 21
Detecting and Managing Faults 29

Table of Contents

Other manuals for Oracle SPARC T8-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T8-1 and is the answer not in the manual?

Oracle SPARC T8-1 Specifications

General IconGeneral
BrandOracle
ModelSPARC T8-1
CategoryServer
LanguageEnglish

Related product manuals