Power the Server Off or On (Oracle ILOM)
42 Oracle X6 Series Servers Administration Guide • April 2016
4.
Use a stylus or other pointed, non-conducting object to press the power button.
The host boots and the server enters Full power mode.
Power the Server Off or On (Oracle ILOM)
You can use Oracle Integrated Lights Out Manager (ILOM) to remotely power on or power off
the server.
Before you perform the following procedure, ensure that you have Admin (a) role privileges in
Oracle ILOM.
Caution - To completely power off the server, you must disconnect the power cords from the
back panel of the server.
Caution - Data loss. An immediate shutdown abruptly closes all applications and files without
saving changes.
1.
To change the server power state in the Oracle ILOM web interface, perform the
following steps:
a.
Log in to the Oracle ILOM web interface.
For instructions, see “Accessing Oracle ILOM” on page 21.
b.
In the navigation pane, click Host Management > Power Control.
c.
In the Select Action drop-down menu, select a power control option.
For descriptions of the power control options, see “Power Control
Options” on page 40.
2.
To change the server power state in the Oracle ILOM command-line interface
(CLI), perform the following steps:
a.
Log in to the Oracle ILOM CLI.
For instructions, see “Accessing Oracle ILOM” on page 21.
b.
Use one of the following commands:
■
To reset the server, type reset /System.
■
To gracefully shut down the server, type stop /System.