Connecting Cables and Applying Power
This section contains procedures for connecting data management and server management
cables and power cords to the server.
■
“Cabling Requirements” on page 71
■
“X7-2 Back Panel Connectors and Ports” on page 72
■
“X7-2L Back Panel Connectors and Ports” on page 73
■
“Preparing for Installation and Power On” on page 78
■
“Logging In to Oracle ILOM and Powering On the Server” on page 79
Related Information
■
“Installation Procedure Overview” on page 11
■
“Using Oracle ILOM” on page 83
Cabling Requirements
Read the following cable requirements for connecting the server.
■
Minimum cable connections for the server:
■
At least one server on-board Ethernet network connection (NET port)
■
Serial management port (SER MGT): Service Processor (SP) local connection for
Oracle ILOM boot messages
■
Power cables for the server power supplies
■
SP management ports:
■
The SER MGT port uses an RJ-45 cable and is always available. This port is the default
connection to the Oracle ILOM SP.
■
The network management port (NET MGT) is the optional connection to the Oracle
ILOM SP. The NET MGT port is configured to use DHCP by default. To set a static
IP address, see “Modifying Network Settings” on page 88. The SP network
management port uses an RJ-45 cable for a 10/100/1000 BASE-T connection.
Connecting Cables and Applying Power 71