SECTION 3: OSCOR MANUAL OPERATION
55 REI OSC-5000E
Sweep Span Listing
The OSCOR can also print the sweep spans stored in memory. This listing will always
include the default sweep spans that are permanently stored in memory.
To plot a listing of the stored sweep spans:
1. Place the OSCOR in the Sweep Mode using the SWEEP/ANALYZE button.
2. Press the RECALL button to display the sweep span list. The RECALL button toggles
the unit between the sweep span list and the frequency spectrum view.
3. Press the PLOT button.
4. A plot may be canceled by pressing MENU.
Analyze Mode and Correlate Mode Plots
To generate a plot of the Analyze Mode or the Correlate Mode:
1. When the desired mode is displayed, press the PLOT button.
2. The plotting process can be canceled by pressing MENU.
Signal Listing
Another useful plot is the signal listing. All the signals stored in the OSCOR database can
be plotted (see page 43 Signal Storage). All signals are plotted in ascending frequency
order. Information about each signal may include threat level, time and date detected,
frequency, antenna input, bandwidth used and demodulator selected. Whether lists are
created in Automatic or Manual Mode, their appearance will be similar. In Automatic
Mode, the type of signal list and their order are determined by the setup (see page 77
Auto Plotting of Threat Signals).
To plot a signal list:
1. Place the OSCOR in the Analyze Mode by pressing the SWEEP/ANALYZE button.
2. Press the RECALL button to display the signal list. The RECALL button toggles the
unit between the signal list and the Analyze Mode spectrum view.
3. Use F1 button to filter the list printing only specific threat levels (i.e. FRIENDLY,
LOW THREATS, THREATS, etc.)
4. Press the MENU button labeled “EDIT MENU”.
5. Press the MENU button labeled “SETUP MENU”.
6. Press F3 to adjust the desired print format (“1 LINE”, “2 LINE”, and
“BLOCKLIST”).
7. Press the PLOT button to print the list that is displayed on the screen using the
print format specified under the CONFIG sub-menu (MENU button).
NOTE: Only the signals that are displayed in the recall mode will be printed. The signal
database can be filtered so that only a certain threat level can be viewed, plotted, or
deleted.
Paper Installation
To properly install the printer paper:
1. With the unit’s power on, remove the printer cover.