Table 1. PMCS - BEFORE - Continued
Item
No.
Interval
Item to
be
Checked
or
Serviced
Procedure
Equipment
Not Ready/
Available If:
kPa). Check that warning buzzer
operates below 60 psi (414 kPa).
kPa) when
low air pres-
sure indica-
tor lights or
warning
alarm
sounds.
9. Check BATTERY gauge (7) for
26 to 30 VDC.
Gauge indi-
cates below
26 VDC or
above 30
VDC.
10. Check BATTERY gauge (8) for
13 to 15 VDC.
Gauge indi-
cates below
13 VDC or
above 15
VDC.
NOTE
At idle, TRANS TEMP gauge
may indicate 0 to 160°F (-18
to 71°C) oil temperature.
11. Check TRANS TEMP gauge (9)
for normal operating temperature
of less than 220°F (105°C).
Gauge indi-
cates in red
area ap-
proximately
300°F
(149°C) or
more.
12. Check T-Case (transfer case)
TEMP gauge (10).
Gauge indi-
cates in red
area 300°F
TM 9-2320-360-10 0100