7.1 Configuration
7.1.1 Setting Communication Conditions
■
Configuration
Setting items Default Specification range Remark
Communication
mode
MEWTOCOL-
COM
MEWTOCOL-COM
MEWTOCOL7-COM
Master communication is not
possible using "MEWTOCOL7".
Station no. 1
MEWTOCOL-COM: 1 to 99, EE
MEWTOCOL7-COM: 1 to 999,
EEE
Set a specific station no. for PLC to
be connected to the PLC link. Set a
value that does not overlap with
other devices.
Baud rate 9600 bps
300 / 600 / 1200 / 2400 / 4800 /
9600 / 19200 / 38400 / 57600 /
115200 / 230400
Set the baud rate to match that of
devices to be connected.
Data length 8 bit 7 bit / 8 bit
The setting must be done according
to the devices connected.
In general, the default values (8-bit
length, odd parity, and 1-stop bit)
should be used.
Parity Odd None / Odd / Even
Stop bit 1 bit 1 bit
RS/CS Invalid Invalid / Valid
Send waiting time
(set value × 0.01
ms)
0
0 to 10000
(0 to 100 ms)
Set this when it is necessary to
delay response to the partner device
in slave communication.
Start code STX Invalid -
No need to specify.
Terminator setting CR -
Terminator judgment
time
(set value × 0.01
ms)
0 -
Modem initialization Do not initialize
Do not initialize / Initialize while
performing settings / Re-
initialize while performing
settings
Perform settings only when a
modem is to be connected. Perform
settings for start-up modem
initialization.
(Note 1) In MEWTOCOL communication, the following setting items need not be specified.
Start code, terminator setting, terminator judgment time, PLC link setting
7.1 Configuration
7-2 WUME-FP7COM-07