Setting Features
Q How do I change the dialing mode of an analog CO line?
A
• From the 3.28 [1-1] Slot—Port Property - LCO Port screen, change the Dialing
Mode setting of the target port to "DTMF" or "Pulse", as required.
Q How do I set disconnect detection (CPC Detection) for an analog CO line?
A
• From the 3.28 [1-1] Slot—Port Property - LCO Port screen, modify the CPC
Signal Detection Time—Outgoing, Incoming setting of the target port.
The required value varies by carrier. Transmission and reception can be set
separately.
Q How do I connect to another PBX using QSIG?
A
• From the 3.31 [1-1] Slot—Port Property - PRI Port screen, set the Port Type of
the port you want to use to either "QSIG-Slave" or "QSIG-Master".
Q How do I change the type of an extension port?
A
• Set the port to OUS status. Then, change DPT Type—Type in the 3.24 [1-1] Slot
—Port Property - Extension Port window
Q I have set the type of an extension port to "DSS Console", but I cannot apply this
setting. (Error E000402)
A
• The number entered in DPT Type—Location No. on the 3.24 [1-1] Slot—Port
Property - Extension Port screen is the same as that entered for another DSS
Console. Change this so that the numbers do not overlap.
Q I have set the type of an extension port to "VM (DPT)", but I cannot apply this setting.
(Error E000403)
A
• The DPT Type—VM Unit No. and DPT Type—VM Port No. settings entered on
the 3.24 [1-1] Slot—Port Property - Extension Port screen are the same as those
entered for another VM (DPT). Change this so that the numbers do not overlap.
Q I have set the type of an extension port to "PC Console", but I cannot apply this
setting. (Error E000402)
A
• The number entered in DPT Type—Location No. on the 3.24 [1-1] Slot—Port
Property - Extension Port screen is the same as that entered for another PC Console.
Change this so that the numbers do not overlap.
Q What programming do I have to perform to use a headset with an extension?
A
• Set Headset OFF/ON on the 3.24 [1-1] Slot—Port Property - Extension Port
screen to "Headset ON".
Q What programming do I have to perform to use XDP with an extension port?
A
• Set XDP Mode on the 3.24 [1-1] Slot—Port Property - Extension Port screen to
"On".
Q How do I edit a Class of Service, or create a new Class of Service?