Ext. No. / Floating Ext. No. (for G-DN)
Specifies the floating extension number of an incoming call distribution group to be accessed.
Default
Not stored.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
6.17 [4-3] DSS Console
Programming Manual References
5.12 [3-5-1] Incoming Call Distribution Group—Group Settings
Feature Manual References
9.1.1 ICD GROUP FEATURES
Ext. No. / Floating Ext. No. (for Message Waiting)
Specifies the number of an extension or floating extension number of an incoming call distribution group for
which messages are checked. If this cell is left empty, the paired extension will check its own messages only.
Default
Not stored.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
6.17 [4-3] DSS Console
Programming Manual References
None