66
Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the VMD
area settings, and the alarm occurrence notification can be configured on this page.
The "Alarm" page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
Configure the settings relating to the alarm action [Alarm]
Click the [Alarm] tab on the "Alarm" page. (☞Pages24and25:Howtodisplay/operatethesetupmenu)
The settings relating to the alarm can be configured in this section. Refer to pages 67 and 69 for further information
about the settings relating to the alarm images and the alarm output terminal.
■ Alarm
[Terminal 1]
Determine how to use terminal 1.
Alarm input: Receives alarms.
Black & white input: Receives the black & white swi-
tchoverinput.(WhentheinputissettoOn,the
black & white mode is activated.)
Off: Not used.
Default:Off
[Terminal 2]
Determine how to use terminal 2.
Alarm output: Alarm output will be carried out accord-
ing to the settings for "Alarm output terminal setup"
(☞ page 69).
Off: Not used.
Default:Off
[Terminal 3]
Determine how to use terminal 3.
AUX output: AUX output will be supplied. The [AUX]
buttons will be displayed on the "Live" page.
Off: Not used.
Default:Off
Note:
• AUXisacameraterminalthatallowsuserstooper-
ate(Open/Close)arbitrarilyfromthe"Live"page.
For example, an operator can remotely control lights
in a place where the camera is installed by connect-
ing the terminal to the light controller.
• Refertotheinstallationguideforfurtherinformation
about input/output rating of each terminal.
• While"Alarminput"isbeingselected,analarmis
detected when the terminal status is changed to
"On".(Default)
It is possible to configure the setting so that an
alarm is detected when the terminal status is
changedto"Off".Refertothe"Readme"fileonthe
providedCD-ROMforfurtherinformationaboutthe
setting.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the
"Alarm" page will be displayed.
[Command alarm]
Select"On"or"Off"todeterminewhetherornotto
receive the command alarm.
The command alarm is the function that provides notifi-
cation of a Panasonic protocol alarm from the other
cameras.When"On"isselected,alarmactionswillbe
performed between multiple cameras.
Default:Off
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available range: 1-65535
Unavailable port number: refer to the help window.
Default: 8181