Version 7.11
58 | Additional Settings and Modes
Digiplex EVO • Programming Guide
Paradox PMC5 Memory Key
WARNING: When using the PMC3 Memory Key, sections [4010], [4011], [4020] and [4021] will not include the labels. When using a PMC4 or PMC5, use
sections [4012] and [4022] to transfer labels.
Figure 4: The PMC5 Memory Key.
Downloading Content from Memory Key to Control Panel
To download content from the memory key to the control panel, proceed as follows:
1. Connect the memory key (PMC5) to the connector labeled
MEM KEY on the control panel.
2. To download the contents of the memory key, except zone numbering and sections [0501] to [0532], enter programming mode, and then access section
[4010]. Depending on the memory key, the labels may or may not be included.
3. To download the contents of the memory key, including zone numbering and sections [0501] to [0532], enter programming mode, and then access section
[4011]. Depending on the memory key, the labels may or may not be included.
4. After the keypad emits a confirmation beep, remove the memory key.
Copy Content from Control Panel to Memory Key
To copy content from the control panel to the memory key, proceed as follows:
1. Connect the memory key (PMC5) to the connector labeled
MEM KEY on the control panel. Ensure that the write-protect jumper on the memory key is ON.
2. To copy the contents to the memory key, except zone numbering and sections [0501] to [0532], enter programming mode, and then access section [4020].
Depending on the memory key, the labels may or may not be included.
3. To copy the contents to the memory key, including zone numbering and sections [0501] to [0532], enter section [4021]. Depending on the memory key, the
labels may or may not be included.
4. After the keypad emits a confirmation beep, remove the memory key. Remove the memory key’s jumper, so you do not accidentally overwrite its contents.
WARNING: When using the PMC3 Memory Key, sections [4010], [4011], [4020] and [4021] will not include the labels. When using a PMC4 or PMC5, use
sections [4012] and [4022] to transfer labels.
Automatic Report Code Programming
When using contact ID or SIA Reporting formats (refer to Worksheet 25 on page 44), default report codes can be programmed automatically. After automatic defaults
are set, they can be changed and the remaining report codes can be set manually.
Table 54: Description of the Paradox PMC5 Memory Key Sections
Section
Description
[4010] Download from the memory key to the control panel, except zone numbering and sections [0501] to [0532].
[4011] Download from the memory key to the control panel, including zone numbering and sections [0501] to [0532].
[4012] Download user labels from the memory key to the control panel.
[4013] Download installer default (used when resetting from memory key to control panel).
[4020] Copy the control panel sections to the memory key, except zone numbering and sections [0501] to [0532].
[4021] Copy the control panel sections to the memory key, including zone numbering and sections [0501] to [0532].
[4022] Copy the control panel user label to the memory key.
[4023] Copy the control panel installer default to the memory key.
Table 55: Description of the Automatic Report Codes
Section
Report Code Description
[4030] All report codes reset to 00
Resets all codes from sections [0201] - [0296], [0701] - [0832], [2001] - [2199], and [3900] - [3999], to 00;
sections [4031] to [4037] reset all the report codes in the following sections, to their default values which
appear in Table 58 on page 60
[4031] All report codes reset to FF [0201] to [0296], [0701] to [0832], [2001] to [2199], and [3900] to [3999]
[4032]
Zone alarm/alarm restore and zone
tamper/tamper restore
[0201] to [0296]
[4033] User/keyswitch arming and disarming [0701] to [0832] and [2001] to [2199]
[4034] Special report codes [3900] to [3909]
[4035] Special arming/disarming report codes [3910] to [3929]
[4036] Special alarm report codes [3930] to [3939]
[4037] Trouble and trouble restore report codes [3940] to [3999]
Locked: Overwriting content is not permitted