Digiplex EVO • Programming Guide
Version 7.11
Additional Options | 43
Additional Options
Use the following section to program additional options on your EVO system. Table 34 on page 43 provides information on sections [3038]. Use Worksheet 21,
Worksheet 22, and Worksheet 23 to record your settings.
WARNING: Since Request for Exit events can occur often, the event buffer may fill up quickly.
Schedule Tolerance Window
AutoTest Report Settings
NOTE: Refer to Table 33 on page 42 for details
Timings
Communication Settings
Use the following section to program communication settings on your EVO system.
Account Numbers
Use Worksheet 24 on page 44 to record your settings.
WARNING: Only the SIA format supports the 0 = 0 digit in its account numbers. Account numbers that use other reporting formats do not support the
0 = 0 digit. In its place, enter A by pressing
STAY (for the K641R/K641LX/K641+ keypads), or by pressing ARM (for the K656 keypad). When using the SIA
format, and the account number transmission (see option 6, in section [3035] on page 41) corresponds to the partition, the control panel only uses the
partition 1 account number programmed in section [3061], but the report code includes the partition number.
Table 34: Description of Section [3038]
Section Option Description OFF ON
Section [3038]
Access Control Options
1Access control feature Disabled
Enabled = Default
* Also includes users with 00 for schedule access.
2
Log Request for Exit in event
buffer*
Disabled
Enabled
3
Log Door Left Open Restore in
event buffer
Disabled
Enabled
4
Log Door Forced Restore in event
buffer
Disabled
Enabled
5 Burglar alarm on forced door Disabled
Enabled
6
Skip exit delay when arming with
access card
Disabled
Enabled
7 Burglar alarm on door left open Disabled
Enabled
8 Who has access during clock loss All users
Masters*
Worksheet 21: Schedule Tolerance Window
Section Data Description Default Setting
[3039] ___/___/___ (x 1 min.) Schedule tolerance window 000
Worksheet 22: AutoTest Report Settings
Section Data Description Default Setting
[3040] ___/___/___ (x 1 day; 000 = disabled) Schedule tolerance window 000
[3041] ___/___ : ___/___ (hr. 00-23 & min. 00-59) AutoTest report time of day 00:00
[3042] ___/___/___ (000-255 x 1 min.) Armed report delay 5 minutes
[3043] ___/___/___ (000-255 x 1 min.) Disarmed report delay 60 minutes
Worksheet 23: Timings Settings
Section Data Description Default Setting
[3051] ___/___/___ (000-255) Ring counter 008
[3052] ___/___/___ (000-255 x 4 sec.) Answering machine delay override delay 32 seconds
[3053] ___/___/___ (000-255 x 2sec.) TLM fail timer 32 seconds
[3054] ___/___/___ (000-127 x 1sec.) Delay between dialing attempts 20 seconds
[3055] ___/___/___ (000-255 x 1 sec.; 000 = instant report) Delay alarm transmission timer 000
[3056] ___/___/___ (000-255 x 1 attempt) Maximum dialing attempts 8 attempts
[3058] ___/___/___ (000-255 x 1 min.; 000 = instant report) Delay power failure report 30 minutes
[3060] ___/___/___ (000-255 x 1 min.) Power failure restore delay report 030 minutes