Version 7.11
Partition Timer Settings | 53
Partition One-touch Options
WARNING: If a keypad is assigned to more than one partition, the one-touch feature must be enabled in all the keypad’s assigned partitions. For instance, to enable the one-touch Regular Arming feature
of a keypad assigned to partitions 1, 2, and 5, enable option 1 of sections [3125], [3225], and [3525].
Partition Special Options
Partition Arming/Disarming Event Call Direction
Table 48: Description of Partition One-Touch Options
Option
Description
Partition 1
[3125]
Partition 2
[3225]
Partition 3
[3325]
Partition 4
[3425]
Partition 5
[3525]
Partition 6
[3625]
Partition 7
[3725]
Partition 8
[3825]
OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON ON ON ON ON
1One-touch regular arming
2 One-touch Stay arming
3One-touch Instant arming
4 One-touch Force arming
5 One-touch Stay or Instant disarming
6 One-touch bypass programming
7 One-touch event display
8 No exit delay when arming with remote control
= Default
Table 49: Description of Partition Special Options
Option
Description
Partition 1
[3126]
Partition 2
[3226]
Partition 3
[3326]
Partition 4
[3426]
Partition 5
[3526]
Partition 6
[3626]
Partition 7
[3726]
Partition 8
[3826]
OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON ON ON ON ON
1 Intellizone delay
2 Intellizone double knockout and zone crossing
3 Intellizone zone crossing
4Auto-force on Stay arming
5 Police code is generated on zone crossing only
6 Future use
----------------
7 Future use
----------------
8 Future use
----------------
= Default
Table 50: Description of Partition Arming/Disarming Event Call Direction
Option
Description
Partition 1
[3127]
Partition 2
[3227]
Partition 3
[3327]
Partition 4
[3427]
Partition 5
[3527]
Partition 6
[3627]
Partition 7
[3727]
Partition 8
[3827]
OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON ON ON ON ON
1 Call telephone number 1/IP receiver 1
2 Call telephone number 2/IP receiver 2
3 Call telephone number 3/IP receiver 3
4 Call telephone number 4/IP receiver 4
5 Backup on telephone number 1/IP receiver 1
6 Backup on telephone number 2/IP receiver 2
7 Backup on telephone number 3/IP receiver 3
8 Backup on telephone number 4/IP receiver 4
= Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series