76 | EN50131 Compliancy
Digiplex EVO • Programming Guide
EN50131 Compliancy
The following sections describe the programming required for your panel to be EN 50131 compliant. To set your panel to be EN 50131 compliant:
1. Enter section [4049] to unlock the software.
2. Enter section [4039] to set all relevant sections to EN 50131compliant default settings.
When your EVO panel is compliant with EN 50131 standards, the following programming sections are enabled and set as default.
PCS Module Programming
Control Panel Settings
System Options
Table 78: PCS Module Programming Section [2950]
Section Option Description OFF ON
Section [2950]
PCS Module Programming
1 GSM reporting See PCS manual
See PCS manual
2 GSM reporting See PCS manual
See PCS manual
3 Future use - - - -
4 Future use - - - -
5
GSM/GPRS no service supervision
Refer to Table 79 on
page 76
Refer to Table 79 on
page 76
6
7 GSM/GPRS module tamper
Disabled Enabled
8 GSM/GPRS RF jamming supervision
Disabled Enabled
Table 79: GSM/GPRS No Service Supervision (options 5 and 6 for Section
[2950] above)
Option
Description
5 6
OFF OFF Disabled
ON OFF When disarmed: trouble only; when armed: trouble only
OFF ON When disarmed: trouble only; when armed: audible only
ON ON Silent alarm becomes audible alarm
Table 80: Control Panel Settings
Section Data Description Default Setting
[3021] __/__ Trouble shutdown (00-15) 10
Table 81: Description of Section [3029]
Section Option Description OFF ON
Section [3029]
System Options 1
1 Enable if using an RTX3 without an K641/ K641+ /K641R Disabled
Enabled
2 Future use ----
3 Future use ----
4 EN 50131 compliant mode
Disabled Enabled
5
Anti-mask supervision
Refer to Table 82 on
page 76
Refer to Table 82 on
page 76
6
7 Generate anti-mask trouble if detected on bypass zone Yes
No
8 Restrict arming on anti-mask trouble Disabled
Enabled
Table 82: Anti-Mask Supervision (options 5 and 6 for Section
[3029] above)
Option
Description
5 6
OFF OFF Disabled
OFF ON Generates trouble only (when armed or disarmed)
ON OFF
When armed: alarm (default)
When disarmed: generates trouble only
ON ON
When armed: alarm
When disarmed: generates audible alarm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series