60 | Additional Settings and Modes
Digiplex EVO • Programming Guide
Automatic Report Codes
Table 58: List of Automatic Report Codes
System Event
Default Contact ID Report Code
(when using sections [4032] to [4037])
Default SIA Report Code
(when using sections [4032] to [4037])
Arming with master code (##) 3 4A1 Close by user CL Closing report
Arming with user code (##) 3 4A1 Close by user CL Closing report
Arming with keyswitch (##) 3 4A9 Keyswitch close CS Closing keyswitch
Auto arming 3 4A3 Automatic close CA Automatic closing
Arm with PC software 3 4A7 Remote arm/disarm CQ Remote arming
Late to close 3 452 Late to close OT Late to close
No movement 3 452 Late to close NA No movement arming
Partial arming 1 456 Partial arm CG Close area
Quick arming 3 4A8 Quick arm CL Closing report
Remote arm (voice) 3 4A7 Remote arm CQ Arm with voice module
Delinquency closing 1 654 System inactivity CD System inactivity
Disarm with master code (##) 1 4A1 Open by user OP Opening report
Disarm with user code (##) 1 4A1 Open by user OP Opening report
Disarm with keyswitch (##) 1 4A9 Keyswitch open OS Opening keyswitch
Disarm after alarm with master code (##) 1 4A1 Open by user OP Opening report
Disarm after alarm with user code (##) 1 4A1 Open by user OP Opening report
Disarm after alarm with keyswitch (##) 1 4A9 Keyswitch open OS Opening keyswitch
Cancel alarm with master code (##) 1 4A6 Cancel OR Disarm from alarm
Cancel alarm with user code (##) 1 4A6 Cancel OR Disarm from alarm
Cancel alarm with keyswitch (##) 1 4A6 Can
cel OS Opening keyswitch
Auto arming cancellation 1 464 Auto-arm time extended CE Closing extend
Cancel alarm with PC software 1 4A6 Cancel OR Disarm from alarm
Voice disarm 1 4A7 Remote arm/disarm OQ Remote disarming
Disarm with PC software 1 4A7 Remote arm/disarm OQ Remote disarming
Disarm after an alarm with PC software 1 4A7 Remote arm/disarm OQ Remote disarming
Quick disarm 1 4A8 Quick disarm OP Opening report
Zone Bypassed (##) 1 57A Zone bypass UB Untyped zone bypass
Zone alarm (##) 1 13A Burglary alarm BA Burglary alarm
Fire alarm (##) 1 11A Fire alarm FA Fire alarm
Early to Disarm by User 1 451 Early to open OK Early to open
Late to Disarm by User 1 452 Late to open OJ Late to open
Zone alarm restore (##) 3 13A Burglary alarm restore BH Burglary alarm restore
Fire alarm restore (##) 3 11A Fire alarm restore FH Fire alarm restore
24-hr Gas alarm (##) 1 13A Burglary alarm GA Gas alarm
24-hr Heat alarm (##) 1 13A Burglary alarm KA Heat alarm
24-hr Water alarm (##) 1 13A Burglary alarm WA Water alarm
24-hr Freeze alarm (##) 1 13A Burglary alarm ZA Freeze alarm
24-hr Gas alarm restore (##) 3 13A Burglary alarm restore GR Gas alarm restore
24-hr Heat alarm restore (##) 3 13A Burglary alarm restore KR Heat alarm restore
24-hr Water alarm restore (##) 3 13A Burglary alarm restore WR Wa
ter alarm restore
24-hr Freeze alarm restore (##) 3 13A Burglary alarm restore ZR Freeze alarm restore
Panic 1: emergency 1 12A Panic alarm PA Panic alarm
Panic 2: medical 1 1AA Medical alarm MA Medical alarm
Panic 3: fire 1 115 Pull station FA Fire alarm
Recent closing 3 459 Recent close CR Recent closing
Police code 1 139 Burglary alarm BM Burglary alarm
Global zone shutdown 1 574 Group bypass CG Close area
Duress alarm 1 121 Duress HA Hold-up alarm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series