Digiplex EVO • Programming Guide
Version 7.11
Additional Settings and Modes | 61
Zone shutdown (##) 1 57A Zone bypass UB Untyped zone bypass
Zone tampered (##) 1 144 Sensor tamper TA Tamper alarm
Zone tamper restore (##) 3 144 Sensor tamper restore TR Tamper restoral
Keypad lockout 1 421 Access denied JA User code tamper
AC failure 1 3A1 AC loss AT AC trouble
Battery failure 1 3A9 Battery test failure YT System battery trouble
Auxiliary supply trouble 1 3AA System trouble YP Power supply trouble
Bell output current limit 1 321 Bell 1 YA Bell fault
Bell absent 1 321 Bell 1 YA Bell fault
Clock lost 1 626 Time/date inaccurate JT Time changed
Fire loop trouble 1 373 Fire trouble FT Fire trouble
TLM trouble restore 3 351 Telco 1 fault restore LR Phone line restoral
AC failure restore 3 3A1 AC loss restore AR AC restoral
Battery failure restore 3 3A9 Battery test restore YR System battery restoral
Auxiliary supply trouble restore 3 3AA System trouble restore YQ Power supply restored
Bell output current limit restore 3 321 Bell 1 restore YH Bell restored
Bell absent restore 3 321 Bell 1 restore YH Bell restored
Clock programmed 3 625 Time/date reset JT Time changed
Fire loop trouble restore 3 373 Fire trouble restore FJ Fire trouble restore
Combus fault 1 333 Expansion module failure ET Expansion trouble
Module tamper 1 145 Exp
ansion module tamper TA Tamper alarm
Module ROM_RAM_error 1 3A4 ROM checksum bad YF Parameter checksum fail
Module TLM trouble 1 352 Telco 2 fault LT Phone line trouble
Module fail to communicate to monitoring station 1 354 Fail to communicate YC Communication fails
Printer fault 1 336 Local printer failure VT Printer trouble
Module AC failure 1 3A1 AC loss AT AC trouble
Module battery failure 1 3A9 Battery test failure YT System battery trouble
Module auxiliary supply trouble 1 3AA System trouble YP Power supply trouble
Combus fault restore 3 333 Expansion module failure restore ER Expansion restoral
Module tamper restore 3 145 Expansion module tamper restore TR Tamper restoral
Module ROM_RAM_error restore 3 3A4 ROM checksum bad restore YG Parameter changed
Module TLM restore 3 352 Telco 2 fault restore LR Phone line restoral
Early to arm by user 3 451 Early to close CK Early to close
Late to arm by user 3 452 Late to close CJ Late to close
Zone excluded on Force arming 1 57A Zone bypass XW Zone forced
Zone went back to arm status 3 57A Zone bypass restore UU Zone included
Printer fault restore 3 336 Local printer failure restore VR Printer restore
Module AC restore 3 3A1 AC loss restore AR AC restoral
Module battery restore 3 3A9 Battery test failure restore YR System battery restoral
Module auxiliary supply restore 3 3AA System trouble restore YQ Power supply restored
Fail to communicate with monitoring station 1 354 F
ail to communicate YC Communication fails
Module RF low battery 1 384 RF transmitter low battery XT Transmitter battery trouble
Module RF supervision trouble 1 381 Loss of supervision - RF US Untype zone supervision
Module RF battery restore 3 384 RF transmitter battery restore XR Transmitter battery restoral
Module RF supervision restore 3 381 Supervision restore - RF UR Untyped zone restoral
Cold start 1 3A8 System shutdown RR Power up
Warm start 1 3A5 System reset YW Watchdog reset
Test report engaged 1 6A2 Periodic test report TX Test repor t
Listen-in request 1 606 Listen-in to follow LF Listen-in to follow
Table 58: List of Automatic Report Codes (Continued)
System Event
Default Contact ID Report Code
(when using sections [4032] to [4037])
Default SIA Report Code
(when using sections [4032] to [4037])

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series