6-20 Programming Your Application
590 Series DC Digital Converter
PROGRAM STOP Tag No. 80 - D:17 TRUE/FALSE
State of program stop (Terminal B8). When B8 is at 24V, then PROGRAM STOP is FALSE
and the program stop front panel LED is also ON.
(Refer to
STOP RATES, page 6-57)
DRIVE START Tag No. 82 - D:18 ON/OFF
Controller start/run command.
(DIAGNOSTIC only)
DRIVE ENABLE Tag No. 84 - D:19 ENABLED/DISABLED
Drive speed and current loop are enabled/quenched.
(DIAGNOSTIC only)
OPERATING MODE Tag No. 212 - D:20
Indicates whether the drive is in RUN, JOG 1....STOP etc.
(Refer to
JOG/SLACK, page 6-32)
FIELD ENABLE Tag No. 169 - D:21 ENABLED/DISABLED
Drive field loop is enabled/quenched.
(Refer to
FIELD CONTROL, page 6-27)
FIELD DEMAND Tag No. 183 - D:22 0.00% to 100.00%
Field current demand.
(Refer to
FIELD CONTROL, page 6-27)
FIELD I FBK Tag No. 300 - D:23 -300.00% to 300.00%
Scaled field current feedback.
(Refer to
CALIBRATION, page 6-11)
FLD.FIRING ANGLE Tag No. 184 - D:24 0 DEG to 180 DEG
Field firing angle in degrees: 155 degrees is the value for back stop (min field) and 5 degrees is
the value for front stop (max field).
(Refer to
FIELD CONTROL, page 6-27)
ANIN 1 (A2) Tag No. 50 - D:25 -100.00 to 100.00 VOLTS
Speed setpoint no. 1.
(Refer to
ANALOG INPUTS, page 6-5)
ANIN 2 (A3) Tag No. 51 - D:26 -100.00 to 100.00 VOLTS
Speed setpoint no. 2/current demand.
(Refer to
ANALOG INPUTS, page 6-5)
ANIN 3 (A4) Tag No. 52 - D:27 -100.00 to 100.00 VOLTS
Speed setpoint no. 3 (ramped).
(Refer to
ANALOG INPUTS, page 6-5)
ANIN 4 (A5) Tag No. 53 - D:28 -100.00 to 100.00 VOLTS
Negative current clamp; this is only active if bipolar clamps are enabled (C6 = ON).
(Refer to
ANALOG INPUTS, page 6-5)
ANIN 5 (A6) Tag No. 54 - D:29 -100.00 to 100.00 VOLTS
Main current limit or positive current clamp if C6 = ON.
(Refer to
ANALOG INPUTS, page 6-5)
ANOUT 1 (A7) Tag No. 55 - D:30 -100.00 to 100.00 VOLTS
Scaled speed feedback.
(Refer to
ANALOG OUTPUTS, page 6-7)
ANOUT 2 (A8) Tag No. 56 - D:31 -100.00 to 100.00 VOLTS
Total speed setpoint.
(Refer to
ANALOG OUTPUTS, page 6-7)
START (C3) Tag No. 68 - D:32 ON/OFF
Start/Run terminal.
(Refer to
AUX I/O, page 6-8)
DIGITAL INPUT (C4) Tag No. 69 - D:33 ON/OFF
Jog/Take-up Slack terminal.
(Refer to
DIGITAL INPUTS, page 6-24 and AUX I/O, page 6-8)