6-10 Programming Your Application
590 Series DC Digital Converter
AUX PORT P2
This function block configures the port for
connecting to a suitable unit, i.e. the 5721
Operator Station for controlling the 5720
Quadraloc controller.
MMI Menu Map
1
SERIAL LINKS
2
AUX PORT P2
SRL LINK ENABLE
GROUP ID (GID)
UNIT ID (UID)
PROTOCOL
BAUD RATE
ESP SUP. (ASCII)
CHANGEBAND (BIN)
ERROR REPORT
PNO.7
AUX PORT P2
ENABLED – [147] SRL LINK ENABLE –
0
–
[140] GROUP ID (GID)
–
0
–
[141] UNIT ID (UID)
–
ASCII
–
[149] PROTOCOL
–
9600
–
[151] BAUD RATE
–
DISABLED
–
[153] ESP SUP. (ASCII)
–
0.00%
–
[145] CHANGEBAND (BIN)
–
00C0
–
[150] ERROR REPORT
–
FFFF
–
[148] PNO. 7
–
Parameter Descriptions
SRL LINK ENABLE
Range: ENABLED/DISABLED
Enables port operation.
GROUP ID (GID)
Range: 0 to 7
The Parker SSD Drives protocol group identity address.
UNIT ID (UID)
Range: 0 to 15
The Parker SSD Drives protocol unit identity address.
PROTOCOL
Range: See below
Selects the protocol to be used. The selections are:
ASCII
BINARY
OPTION (select OPTION if say a Profibus option is fitted)
BAUD RATE
Range: See below
Selects the Baud Rate.
300
600
1200
2400
4800
9600 (default)
19200
ESP SUP. (ASCII)
Range: ENABLED/DISABLED
Enable if communicating with a unit using Parker SSD Drive’s own ESP protocol.
CHANGEBAND (BIN)
Range: 0.00% to 327.67%
Percentage change in value to trigger a BINARY Enquiry Poll update.
ERROR REPORT
Range: 0000 to FFFF
Displays the last error as a hexadecimal code. Writing any value to this parameter will set the
value to >00C0 (No Error). Refer to Chapter 14: “Serial Communications” - Reference for a list
of codes.
PNO. 7
Range: 0000 to FFFF
Control word for Multi-Parameter Polling (refer to the COMMS Option Board Technical
Manual - Parameter Specification Tables.