Programming Your Application 6-9
590 Series DC Digital Converter
Functional Description
In the case of auxiliary digital inputs AUX START, AUX JOG and AUX ENABLE, the overall
input will be the result of the "AND" gating of the normal terminal signal with the auxiliary
signal.
In the case of the digital and analog outputs, the relevant Tag No’s are internal memory
locations which can be attached by configuration to the digital or analog output terminals and
are controlled by the serial links or the MMI.
ANOUT 1 & 2 can also be used as general "staging posts" for connecting inputs to outputs.
Example: Connect Analog Input 1 (A2) directly to Analog Output 1 (A7)
TAG # PARAMETER
DEFAULT
SETTING
161 AUX START ON
227 AUX JOG
ON
168
AUX ENABLE
ON
CONFIGURABLE AUX I/O POINTS
NOTE (2)
94
AUX DIGOUT 1
OFF
95
AUX DIGOUT 2
OFF
96
AUX DIGOUT 3
OFF
128
ANOUT 1
129
ANOUT 2
0.00%
0.00%
94
95
96
128
129
AUX I/O
JOG
RUN
TO DRIVE ENABLE
NOTE (1) DC CONTACTOR AM AUXILIARY
INTERLOCK WITH DRIVE ENABLE
68
C3
D:32
START
69
C4
D:33
JOG
70
C5
D:34
AM
C9
Note (1)
+24V
NOTE (2) 3 CONFIGURABLE DIGITAL AND 2 CONFIGURABLE
ANALOG AUX POINTS ARE AVAILABLE. THESE AUX
I/O POINTS ALLOW INPUTS OR SERIAL INFORMATION
TO BE CONNECTED TO OUTPUTS. (INPUTS MAY BE
SENT TO THESE TAG DESTINATIONS AND OUTPUTS
MAY READ THESE LOCATIONS AS SOURCE TAGS).
ENABLE
TO DRIVE START
TO JOG/SLACK
ANOUT 1
Destination Tag = 128 Source Tag = 128
ANIN 1 (A2) ANOUT 1
Tag No. 128