6-22 Programming Your Application
590 Series DC Digital Converter
DIAMETER CALC.
This block calculates the diameter of a reel
as a function of the reel speed and the line
speed.
DIAMETER CALC.
–
DIAMETER [427]
MMI Menu Map
1
SETUP PARAMETERS
2
SPECIAL BLOCKS
3
DIAMETER CALC.
LINE SPEED
REEL SPEED
MIN DIAMETER
MIN SPEED
RESET VALUE
EXTERNAL RESET
RAMP RATE
DIAMETER
Parameter Descriptions
LINE SPEED
Range: -105.00 to 105.00 %
This will usually be configured to be the analog tacho input and scaled appropriately during
calibration.
REEL SPEED
Range: -105.00 to 105.00 %
This will usually be configured to be the drive's own speed feedback, i.e. encoder or arm.volts
feedback
MIN DIAMETER
Range: 0.00 to 100.00 %
This is normally the empty core diameter.
MIN SPEED
Range: 0.00 to 100.00 %
This is the minimum LINE SPEED level below which the diameter calculation is frozen.
RESET VALUE
Range: 0.00 to 100.00 %
Normally for winders this will be set to the MIN DIAMETER value. This value will be
preloaded into the ramp (filter) output when EXTERNAL RESET is enabled.
EXTERNAL RESET
Range: ENABLED/DISABLED
Whilst this input is being enabled the ramp is held at the RESET VALUE.
RAMP RATE
Range: 0.1 to 600.0 SECS
This is used to filter the output of the diameter calculator.
DIAMETER
Range: 0.00 to 100.00 %
This is the output of the block and it can be connected to the appropriate points in the winder
block.
MOD OF LINE SPEED
Reserved parameter for use by Parker SSD Drives.
MOD OF REEL SPEED
Reserved parameter for use by Parker SSD Drives.
UNFILTERED DIAMETER
Reserved parameter for use by Parker SSD Drives.