Programming Your Application 6-45
590 Series DC Digital Converter
Functional Description
RAMP INPUT
MIN. SPEED
Jog /
I/P
O/P
1
0
RAMP DECEL TIME
RAMP ACCEL TIME
RAMP HOLD
AUTO RESET
EXTERNAL RESET
RESET VALUE
Slack
"S" RAMP
0
I/P
O/P
t
% S-RAMP
RAMPING THRESH.
RAMPING
RAMP OUTPUT
MIN SPEED
Range: 0.00 to 100.00 %
The minimum speed clamp is fully bi-directional and operates with a 0.5% hysterisis. This
clamp operates on the input to the ramp and it can therefore be overridden by the RESET
VALUE as far as the ramp output is concerned.
RAMP OUTPUT
Refer to the DIAGNOSTICS function block description, page 6-
18.
RAMPING
Refer to the DIAGNOSTICS function block description, page 6-
18.
Input
Output
Minimum Speed
-0.5
0
0.5