11-2 Technical Specifications
590 Series DC Digital Converter
External AC Supply (RFI) Filters and Line Choke
Filters must only be fitted on the mains side of the contactor.
Always use the recommended external AC Line Choke.
AC supply filter and line choke part numbers for conformance with EN55011 Class A.
Armature Current Rating
(A)
Total Filter Watt Loss
(W)
Parker SSD Filter Part No. SSD EMC Line Choke
35
25
1 off CO388965U035 CO463036
70 75 1 off CO388965U110 CO463037
110 75 1 off CO388965U110 CO463038
150, 180 158 1 off CO388965U180 CO463039
270 50 1 off CO467843U340 CO057960
360 50 1 off CO467843U340 CO057961
450 100 2 off CO467843U340 CO057962
720 100 2 off CO467843U340 CO057963
800 100 3 off CO467843U340 CO057963
AC supply filter part numbers for “non CE marked” converters.
Armature Current Rating
(A)
Total Filter Watt Loss
(W)
Parker SSD Filter Part No. Line Choke Requirement
950, 1100 150 3 off CO467843U340
1388 200 4 off CO467843U340 2% minimum,
1600, 1800 250 5 off CO467843U340 refer to
2300 350 7 off CO467843U340 Parker SSD Drives
2800 400 8 off CO467843U340
Cabling Requirements for EMC Compliance
Model Power Supply
Cable
Motor Cable External Filter to Converter Cable
Signal/Control
Cable
Cable Type
(for EMC Compliance)
Unscreened Screened/
armoured
Replace flying leads with
screened/armoured when >0.6m
Screened
Segregation From all
other wiring
(clean)
From all other wiring (noisy) From all other
wiring (sensitive)
Length Limitations
With External Filter
Unlimited 50 metres As short as possible
25 metres
Screen to Earth
Connection
Both ends Both ends
Converter end
only