Installing the Converter 3-1
590D DC Digital Converter - HA467078
3INSTALLING THE CONVERTER
IMPORTANT: Read Chapter 12: “Certification for the Converter” before installing this unit.
Refer to
24
HInstallation Drawings, page 3-
25
H20 for further information.
Mechanical Installation
35A - 70A
C
D
B
E1
A
110A - 150A
C
D
A
B
E1
A
C
D
B
E1
180A - 270A
C
D
B
E1
A
360A
C
D
B
E2
E1
E1
720A - 800A *
A
450A *
C
D
B
E1
A
* Cooling fan assemblies not shown
Current Rating (A) Model Overall Dimensions Fixing Centres
A B C D E1 E2
35 - 70 590D/591D 250 415 180 200 400 -
110 - 150 590D/591D 250 445 180 200 400 -
180 590D/591D 250 555 180 200 400 -
270 590D/591D 300 500 210 200 400 -
360 & 450 590D/591D 322 705 252 200 600 -
720 & 800 590D/591D 370 930 330 300 133 400
Dimensions are in millimetres