14-10 Serial Communications
590 Series DC Digital Converter
Error Codes
ERROR REPORT (EE)
The EI-BISYNCH Prime Set contains the EE mnemonic. This is also an output parameter in the
MAIN PORT (P1), AUX PORT (P2) and SYSTEM PORT (P3) function blocks, where the
parameter value can be read and reset. Refer to the COMMS Option Technical Manual for
further details.
The following values are returned if an enquiry (reading information from the Converter) is
performed on this Read/Write parameter.
Writing any value to this parameter will set the value to >00C0. Clearing the last error value
may be useful in seeing a repetitive error re-occurring.
Value Description
>00C0 No error
>01C7 Invalid mnemonic
>02C2 Checksum (BCC) error
>03C2 Framing or overrun error
>04C8 Attempt to read from a write-only parameter
>05C8 Attempt to write to a read-only parameter
>07C7 Invalid message format
>07C8 Invalid data (encoding error)
>08C8 Data out of range