EasyManua.ls Logo

Parker 590 series - Which Standards Apply?; Basic and Generic Standards

Parker 590 series
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-10 Certification for the Converter
590 Series DC Digital Converter
Which Standards Apply?
Basic and Generic Standards
The standards that may apply to this unit come under two broad categories:
1. Emission - these standards limit the interference caused by operating (this) drive module.
2. Immunity - these standards limit the effect of interference (on this unit) from other electrical
and electronic apparatus.
The following table indicates the standards that the unit may comply with, dependent upon how
it is installed and used.
Unit used as
Relevant Apparatus
Unit used as a
Component
Assuming installation to EMC instructions in this manual
“Filter” refers to a specified external filter.
filter
(EMC
compliance)
no filter filter
(EMC
compliance
may be
applied for)
no filter
Installation Basic and Generic Standards
enclosure enclosure enclosure enclosure
Radiated RF Emission
EN55022 Class B (1994)
or
EN50081-1 (1992)
Residential Conducted RF
Emission
EN55022 Class B (1994)
or
EN50081-1 (1992)
Immunity EN50082-1 (1992)
Radiated RF Emission
EN55022 Class B (1994)
or
EN50081-1 (1992)
Commercial &
Light Industry
Conducted RF
Emission
EN55022 Class B (1994)
or
EN50081-1 (1992)
Immunity EN50082-1 (1992)
Radiated RF Emission
EN55011 Class A (1991)
or
EN50081-2 (1994)
Industrial Conducted RF
Emission
EN55011 Class A (1991)
or
EN50081-2 (1994)
Immunity prEN50082-2 (1992)
Table 12-1 Applicable Basic and Generic Standards

Table of Contents

Other manuals for Parker 590 series

Related product manuals