Technical Specifications 11-15
590 Series DC Digital Converter
Termination Tightening Torque
Product Terminations Maximum Tightening Torque
ALL A1 - A9
B1 - B9
C1 - C9
M2.5 5-7lb.in. 0.56-0.79Nm
M2.5 5-7lb.in. 0.56-0.79Nm
M2.5 5-7lb.in. 0.56-0.79Nm
35 - 720 Amps D1 - D8 M3 4lb.in. 0.45Nm
35 - 180 Amps A+, A-, L1, L2, L3
Ground
M8 8.1lb.ft. 11.0Nm
M6 5.0lb.ft. 6.8Nm
270 Amps A+, A-, L1, L2, L3
Ground
M8 12.2lb.ft. 16.5Nm
M6 5.0lb.ft. 6.8Nm
360 - 450 Amps A+, A-,
L1, L2, L3
Ground
M10 24.2lb.ft. 32.8Nm
M12 42.2lb.ft. 57.2Nm
M10 24.2lb.ft. 32.8Nm
720 Amps A+, A-,
L1, L2, L3
Ground
M10 24.2lb.ft. 32.8Nm
M14 67.1lb.ft. 91.0Nm
M8 12.2lb.ft 16.5Nm
Mechanical Details
Mounting Orientation Vertical. Refer to Chapter 3: “Mechanical installation” for dimensions and air clearances.
590/591
Up to 70A Up to 150A Up to 180A 270A 450A 720A
Nominal Blower
Throughput (m³/hour)
- 100 300 350 490 1000 (at 80
millibar for
rated output)
Weight (kg (lbs)) 10-14 (22-30) 15 (33.2) 17 (37.5) 20 (44) 30 (66) 65 (143)
Power Terminations Bus bars with M8 screws and captive nuts AC terminals::
bus bars with
M8 screws and
captive nuts
DC terminals::
M8 bolts with
nuts and
washers
AC bus bars
with M12
screws and
captive nuts
AC bus bars
with M14
screws and
captive nuts
Control Terminations Plug-on connectors with retaining catches
598/599 module exceeding 720A
Weight (kg (lbs)) 10-14 (22-30)
Power Terminations Bus bars with M8 screws and captive nuts
Control Terminations Control Board: Plug on connectors with retaining catches
Current Feedback/Coding Low Volts: Screw in with wire protectors
Coding High Volts/Armature Feedback: M5 studs with nuts and washers